W1 & W2 WINDCODE® Drawings

NOTE: CHECK WITH YOUR LOCAL BUILDING CODE DEPARTMENT FOR MINIMUM REQUIREMENTS IN YOUR JURISDICTION

WINDCODE® garage doors, when installed as described in the provided drawings, have been tested in accordance with ASCE7-98 (2000 International Building Code or 2000 International Residential Code) using test standards ASTM E330 or DASMA 108 for the following design wind load pressures (with test loads equal to 150% of design loads).

W1 Model Numbers
Maximum Size
Design Wind Load Pressures (PSF)
Test Wind Load Pressures (PSF)
WINDCODE® Drawing PDF
Width
Height
Positive
Negative
Positive
Negative
73, 75, 75L, 76, 84A, 94, 1500, 42, 46, 48
9'-0"
8'-0"
13.0
15.0
19.5
22.5
73, 75, 75L, 76, 84A, 94, 1500 , 42, 46, 48
16'-0"
8'-0"
12.5
14.0
19.0
21.0
73, 75, 84A, 94, 1500, 42, 48
18'-0"
8'-0"
12.5
14.0
19.0
21.0
H73, H76, H94, H500
9'-0"
12'-0"
13.0
15.0
19.5
22.5
H73, H76, H94, H500
16'-0"
12'-0"
12.5
14.0
19.0
21.0
H76, H94, H500
18'-0"
12'-0"
12.5
14.0
19.0
21.0
1000, 1001, 1100, 183, 186, 187, 52, 54
9'-0"
8'-0"
13.0
15.0
19.5
22.5
1000, 1001, 1100, 183, 186, 187, 52, 54
16'-0"
8'-0"
12.5
14.0
19.0
21.0
1000, 1001, 183, 187, 52
18'-0"
8'-0"
12.5
14.0
19.0
21.0
H000, H001, H100
9'-0"
12'-0"
13.0
15.0
19.5
22.5
H000, H001, H100
16'-0"
12'-0"
12.5
14.0
19.0
21.0
H000, H001
18'-0"
12'-0"
12.5
14.0
19.0
21.0
2050, 2051, 4050, 4051, 4053, 62, 64, 65
9'-0"
8'-0"
13.0
15.0
19.5
22.5
2050, 2051, 4050, 4051, 4053, 62, 64, 65
16'-0"
8'-0"
12.5
14.0
19.0
21.0
2050, 2051, 4050, 4051, 4053, 62, 64, 65
18'-0"
8'-0"
12.5
14.0
19.0
21.0
H050, H051, H053
9'-0"
12'-0"
13.0
15.0
19.5
22.5
H050, H051, H053
16'-0"
12'-0"
12.5
14.0
19.0
21.0
H050, H051, H053
18'-0"
12'-0"
12.5
14.0
19.0
21.0
4300, 4301, 4310, 4400, 4401, HDG, HDGL, 66, 67, 68
9'-0"
8'-0"
13.0
15.0
19.5
22.5
4300, 4301, 4310, 4400, 4401, HDG, HDGL, 66, 67, 68
16'-0"
8'-0"
12.5
14.0
19.0
21.0
4300, 4301, 4310, 4400, 4401, HDG, HDGL , 66, 67, 68
18'-0"
8'-0"
12.5
14.0
19.0
21.0
H300, H301, H310, H400, H401
9'-0"
12'-0"
13.0
15.0
19.5
22.5
H300, H301, H310, H400, H401
16'-0"
12'-0"
12.5
14.0
19.0
21.0
H300, H301, H310, H400, H401
18'-0"
12'-0"
12.5
14.0
19.0
21.0
RHxx, RRxx, RCxx (Reserve Collection™)
9'-0"
8'-0"
20.0
21.0
30.0
31.5
RHxx, RRxx, RCxx (Reserve Collection™)
16'-0"
8'-0"
12.5
14.0
19.0
21.0
251S, 251L, 251F, B178, B278, B378 , 55S, 55L
9'-0"
12'-0"
13.0
15.0
19.5
22.5
251S, 251L, 251F, B178, B278, B378, 55S, 55L
16'-0"
12'-0"
12.5
14.0
19.0
21.0
251S, 251F, B178, B378, S51S, S51F, 55S
18'-0"
12'-0"
12.5
14.0
19.0
21.0
150S, C125, 140S, C124 , 45S, 44S, B5S, B4F, B4S
18'-0"
12'-0"
12.5
14.0
19.0
21.0
150S, C125, 140S, C124 , 45S, 44S, B5S, B4F, B4S
18'-0"
12'-0"
12.5
14.0
19.0
21.0
150S, C125, 150L, C225, 140S, C124, 140L, 44S, B4S, B42, B4E, B5S, B5L, 45S, 45L
9'-0"
12'-0"
13.0
15.0
19.5
22.5
GS4V, G4L, GL4, G4LV, GL4V,SS4,SS4V,SL4,SL4V,E4S, E4SV, E4L, E4LV
9'-0"
12'-0"
13.0
15.0
19.5
22.5
G4S, GS4, G4SV, GS4V,SS4,SS4V,SL4,SL4V, E4S, E4SV, E4L, E4LV
16'-0"
12'-0"
12.5
14.0
19.0
21.0
G4S, GS4, G4SV, GS4V, G4L, GL4,SS4,SS4V,SL4, E4S, E4SV, E4L
18'-0"
12'-0"
12.5
14.0
19.0
21.0

 

W2 Model Numbers
Maximum Size
Design Wind Load Pressures (PSF)
Test Wind Load Pressures (PSF)
WINDCODE® Drawing PDF
Width
Height
Positive
Negative
Positive
Negative
73, 75, 84A, 94, 1500, 42, 48, 6RST, 4RST, 6RSF, 4RSF
9'-0"
8'-0"
16
15.8
24
27.5
73, 75, 84A, 94, 1500, 42, 48, 6RST, 4RST, 6RSF, 4RSF
16'-0"
8'-0"
15.5
17
23
25.5
H73, H94, H500, H6ST, H6SF, H4ST
9'-0"
12'-0"
16
18.5
24
27
H73, H94, H500, H6ST, H6SF, H4ST
16'-0"
12'-0"
15.5
17
23
25.5


Close Window
Terms of Use    Privacy    Site Map    © 2008 Clopay
Home | Residential Garage Doors | Commercial Garage Doors